20% OFF shipping at nealswaterconditioning.com on orders over $79 + up to 10% OFF products
nealswaterconditioning.com
home > Kidde Firex 5x KF20LL Optical Smoke & 1x KF30LL Heat Alarm Kit Mains Powered with Long-Life 9V Lithium Battery Back-Up > Kidde Firex 5x KF20LL Optical Smoke & 1x KF30LL Heat Alarm Kit Mains Powered with Long-Life 9V Lithium Battery Back-Up
download picture
Kidde Firex 5x KF20LL Optical Smoke & 1x KF30LL Heat Alarm Kit Mains Powered with Long-Life 9V Lithium Battery Back-UpKidde Firex 5x KF20LL Optical Smoke & 1x KF30LL Heat Alarm Kit Mains Powered with Long Life 9V Lithium Battery Back Up FULLY COMPLY WITH THE NEW 2022 SCOTTISH & WELSH REGULATIONS 5x Mains Powered Optical Smoke Alarm (KF20LL): Mains Optical Smoke Alarm Features: Mains powered optical smoke alarm that can be interlinked with up to 23 other Kidde mains alarms, be they ionisation, optical or heat. Once interlinked, the detection of the relevant danger by
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Kidde Firex 5x KF20LL Optical Smoke & 1x KF30LL Heat Alarm Kit Mains Powered with Long-Life 9V Lithium Battery Back-Up

FULLY COMPLY WITH THE NEW 2022 SCOTTISH & WELSH REGULATIONS

5x Mains Powered Optical Smoke Alarm (KF20LL):

Mains Optical Smoke Alarm Features:

Mains-powered optical smoke alarm that can be interlinked with up to 23 other Kidde mains alarms, be they ionisation, optical or heat.
Once interlinked, the detection of the relevant danger by an individual unit will sound across all the connected alarms.
Optical alarms are for use in escape or circulation routes and in areas where there is a danger of ignition of furniture and surroundings by cigarettes producing slow, smouldering fires.
This mains-powered unit should be installed by a qualified electrician and can be used throughout the home, except in the kitchen where a Firex Heat Alarm is recommended. These alarms comply with UK Building Regulations for new housing and associated standards (Grade D BS 5839, Part 6).

  • Interlink with up to 23 Firex hard-wired alarms – all alarms sound if danger is detected
  • Alarm memory – identifies source unit within interconnecting network
  • Combined Test/Hush button allows regular testing of alarm function and can be used to temporarily silence nuisance alarms
  • Auto reset after activation
  • Tamper-resistant locking device – prevents unauthorised removal without the use of a tool
  • Mains operation – 9V Lithium back-up battery supplied as standard

Mains Optical Smoke Alarm Specification:

  • Model KF20LL
  • Power Supply 230V mains-powered with 9V Lithium battery back-up
  • Temperature Range 0ºC to + 40ºC
  • Humidity Range Up to 93% Relative Humidity (RH) non-condensing
  • Storage and Transport -20ºC to +60ºC and 5–95% relative humidity (RH) non-condensing
  • Alarm Dimensions 127 x 127 x 39mm
  • Bracket Dimensions 133 x 133 x 6mm
  • Alarm Weight 242g
  • Warranty 6 years
  • Approvals BSI certified to BS EN14604:2005
  • CE tested and certified Sensor Optical, circular lateral chamber with insect-resistant width slot entry portals and added bug screen mesh
  • Chamber Size 35mm outside diameter x 16mm depth approximate (external)
  • Detection Band Infrared light wavelength
  • Button Test Simulates the effect of smoke within the sensing chamber, checks electronics and sounder
  • Automatic Self-test Circuitry is tested and unit beeps (chirps) if fault is detected
  • Supply Voltage 230V AC, 50 Hz (nominal UK voltage)
  • Power Consumption < 15mA
  • Connection Push-in/snap-fit type connector with 150mm long flying leads (supplied)
  • Battery Back-up User-replaceable alkaline 9V battery (522/6LR61)
  • Power-on Indicator Continuous green LED
  • Alarm Sounder Electronic piezo-electric sounder (T3 pattern sound - 3 pulses - space - 3 pulses), soldered contacts
  • Sound Output 85dB (A) minimum at 3 metres
  • Alarm Frequency 3.2 kHz typical
  • Dust Protection In-built foam gasket in rear of alarm to prevent dust ingress into rear of the alarm
  • Alarm Status Red LED flashes approx once every five minutes = normal operation
  • Red LED flashes once a second = sensing smoke (sounder alarm sounds)
  • Red LED flashes once every ten seconds = in hush condition (auto-reset after 15 minutes)
  • Interconnection Up to 24 Firex and Kidde ‘Slick’ units (smoke, heat and CO) can be hardwire interconnected with optional control (see below)
  • Optional Controls Wired Remote Test and Hush Unit (REMTH) allows test and hush of interlinked units
  • Optional Pattresses SMK23RU also has integral switchable relay for operating remote devices
  • SMK4896 – Surface mounting base for added ease of installation
  • Fixing Mounting bracket ring supplied with two ‘T’ slot fitting option
  • 57mm spacing to a maximum of 90mm for standard screw fittings on back boxes
  • Bracket has 50mm diameter central access hole for cabling
  • Plastics used NORYL – Cover, main body and mounting bracket
  • Lead-Free Status All Firex alarms are lead-free

1x Mains Powered Heat Alarm (KF30LL):

Mains Heat Alarm Features:

Mains-powered heat alarm that can be interlinked with up to 23 other Kidde mains alarms, be they ionisation, optical or heat.
Once interlinked, the detection of the relevant danger by an individual unit will sound across all the connected alarms.
Mains-powered heat alarms can be used throughout the home in humid or dusty environments where an optical or ionisation smoke alarm is unsuitable, e.g. kitchens, loft spaces and garages.
The Firex range requires installation by a professionally qualified electrician and complies with UK Building Regulations for new housing and associated standards (Grade D BS 5839, Part 6).

  • Interlink with up to 23 Firex hard-wired alarms – all alarms sound if danger is detected
  • Alarm memory – identifies source unit within interconnecting network
  • Combined Test/Hush button allows regular testing of alarm function and can be used to temporarily silence nuisance alarms
  • Auto reset after activation
  • Tamper-resistant locking device – prevents unauthorised removal without the use of a tool
  • Mains operation – 9V Lithium back-up battery supplied as standard

Mains Heat Alarm Specification:

  • Model KF30LL
  • Power Supply 230V mains-powered with 9V Lithium battery back-up
  • Temperature Range 0ºC to + 40ºC
  • Humidity Range Up to 93% Relative Humidity (RH) non-condensing
  • Storage and Transport -20ºC to +60ºC and 5–95% relative humidity (RH) non-condensing
  • Bracket Dimensions 127 x 127 x 39mm
  • Alarm Dimensions 133 x 133 x 6mm
  • Alarm Weight 213g
  • Warranty 6 years
  • Approvals BSI certified to BS5446 Part 2: 2003
  • CE tested and certified
  • Sensor Thermistor (Thermal Resistor) within detection unit
  • Button Test Simulates the effect of heat at the sensor, checks electronics and sounder
  • Automatic Self-test Circuitry is tested and unit beeps (chirps) if fault is detected
  • Supply Voltage 230V AC, 50 Hz (nominal UK voltage)
  • Power Consumption < 15mA
  • Connection Push-in/snap-fit type connector with 150mm long flying leads (supplied)
  • Battery Back-up User replaceable alkaline 9V battery (522/6LR61)
  • Power-on Indicator Continuous green LED
  • Alarm Sounder Electronic piezo-electric sounder (T3 pattern sound - three pulses - space - three pulses) with soldered contacts
  • Sound Output 85dB (A) minimum at 3 metres
  • Alarm Frequency 3.2 kHz typical
  • Alarm Status Red LED flashes approx once every five minutes = normal operation
  • Red LED flashes once a second = sensing heat in excess of 58ºC (sounder alarm sounds)
  • Interconnection Up to 24 Firex and Kidde ‘Slick’ units (smoke, heat and CO) can be hardwire interconnected with optional control (see below)
  • Optional Controls Wired Remote Test and Hush Unit (REMTH) allows test and hush of interlinked units
  • Optional Pattresses SMK23RU also has integral switchable relay for operating remote devices
  • SMK4896 – Surface mounting base for added ease of installation
  • Fixing Mounting bracket ring supplied with two ‘T’ slot fitting option
  • 57mm spacing to a maximum of 90mm for standard screw fittings on back boxes
  • Bracket has 50mm diameter central access hole for cabling
  • Plastics used NORYL – Cover, main body and mounting bracket
  • Lead-Free Status All Firex alarms are lead-free

Please note: Alarms are sold individually.

Data Sheet:

Data Sheet for KF20LL
Data Sheet for KF30LL

Instruction Manual:

Instruction Manual for KF20LL
Instruction Manual for KF30LL

Kidde Firex 5x KF20LL Optical Smoke & 1x KF30LL Heat Alarm Kit Mains Powered with Long-Life 9V Lithium Battery Back-Up

Item no : 34815709281
sold recently : Login >>
US$ 139.00
Pay in 4 interest-free payments of $34.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 21 - Jun 26

Enjoy 20% off shipping

US$ 139.00

1-11

US$ 125.10

12-35

US$ 97.30

36-59

US$ 83.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches