The Tektronix P5200, P5205, and P5210 High Voltage Differential Probes are active differential probes that let users safely make measurements of floating circuits while keeping the oscilloscope grounded. Each probe converts floating signals into low-voltage, ground-referenced signals that can be displayed safely and easily on any ground-referenced oscilloscope. The P5200 can be used with any oscilloscope; the P5205 and P5210 connect to Tektronix oscilloscopes through the TEKPROBE interface or to any oscilloscope by way of the 1103 TEKPROBE Power Supply.
These probes are built for floating measurements in power-electronics work. Listed applications include switching power supply design, motor drive design, electronic ballast design, CRT display design, power converter design and service, and power device evaluation. The P5205, a 100 MHz active differential probe, is designed to capture fast rise times in floating circuits and can safely measure voltages in IGBT circuits such as motor drives and power converters.
ValueTronics stocks this equipment in our own 20,000 sq ft secure warehouse at 1675 Cambridge Drive, Elgin, Illinois. Every pre-owned unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer.
Tektronix, Inc. has retained its brand name throughout its corporate history. It was acquired by Danaher Corporation in 2007 and became part of Fortive Corporation when Fortive was spun off from Danaher in 2016.
The P5200, P5205, and P5210 make up Tektronix's High Voltage Differential Probe family. All three are active differential probes that convert floating signals into low-voltage, ground-referenced signals so they can be displayed safely on a grounded oscilloscope, and all three offer switchable attenuation and a switchable bandwidth limit.
Within the family the models differ in bandwidth, differential and common mode voltage ratings, attenuation factors, input resistance, and power source. The P5200 operates from an AC wall adapter and works with any oscilloscope, while the P5205 and P5210 are powered from the TEKPROBE Power Supply and connect through the Tektronix TEKPROBE interface.
Each model below is its own dedicated product page with pre-owned-matched pricing. Select the model that fits your bandwidth and voltage requirements, then choose the listing that matches the condition you need.
The P5200 is the most broadly compatible member of the family: it runs from an AC wall adapter and can be used with any ground-referenced oscilloscope, rather than requiring the TEKPROBE interface used by the P5205 and P5210.
The clearest differences are bandwidth and voltage. Bandwidth is 25 MHz on the P5200, 100 MHz on the P5205, and 50 MHz on the P5210. The P5210 carries the highest voltage ratings — 4400 V differential (RMS or DC), 5600 V differential peak, and 2200 V CAT II / 1000 V CAT III common mode — while the P5200 and P5205 are each rated 1000 V CAT II differential, 1300 V differential peak, and 1000 V CAT II / 600 V CAT III common mode. See the comparison table for the full row-by-row figures.
Attenuation, input resistance, and power source also vary. The P5200 and P5205 use 50X/500X switchable attenuation with 4 MΩ input resistance per input, whereas the P5210 uses 100X/1000X attenuation with 8 MΩ input resistance per input. The P5200 is powered by an AC wall adapter; the P5205 and P5210 are powered by the TEKPROBE Power Supply. CMRR (80 dB / 50 dB typical) and 7 pF input capacitance are shared across all three.
| Model | Bandwidth | Max Differential Voltage (Peak) | Max Common Mode Voltage |
|---|---|---|---|
| P5205 | 100 MHz | 1300 V | 1000 V CAT II |
| P5200 | 25 MHz | 1300 V | 1000 V CAT II |
| P5210 | 50 MHz | 5600 V | 2200 V CAT II |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Characteristics | |
| Bandwidth (–3 dB) | 100 MHz |
| Differential Mode Voltage (RMS or DC) (between positive and negative input leads) | 1000 V CAT II |
| Differential Mode Voltage (Peak) (between positive and negative input leads) | 1300 V |
| Common Mode Voltage (RMS or DC + Pk AC) (between positive lead and ground or negative lead and ground) | 1000 V CAT II / 600 V CAT III |
| Attenuation (switchable) | 50X/500X |
| CMRR at 60 Hz/1 MHz (typical) | 80 dB/50 dB |
| Input R (each input) | 4 MΩ |
| Input C (each input) | 7 pF |
| Power Source | TEKPROBE Power Supply |
| Safety | UL3111-1/CSA1010.1/CSA1010.2.031/IEC61010-2-031/EN61010-2-031 |
| Compatible Products | TDS400/500/600/700/TDS3000B/5000B/6000B/7000B/CSA7000B and 11000 Series |
Important: WARNING: For safe operation, do not use the P5200 High Voltage Differential Probe with oscilloscopes that have floating inputs (isolated inputs), such as the Tektronix TPS2000 Series and THS700 Series. The P5200 requires an oscilloscope or other measurement instrument with grounded inputs.
Important: The RMS value of the waveform shall not exceed the Common Mode Voltage (RMS) for either lead.
Important: TDS7154B, TDS7254B, TDS7404B, TDS6404, TDS6604, CSA7154, and CSA7404B require a TCA-1MEG Buffer Amplifier.
Important: The P5205 and P5210 are powered through the oscilloscope's TEKPROBE interface. For use with an oscilloscope that does not have a TEKPROBE interface, the 1103 TEKPROBE Power Supply (order 1103) is required and is not included with the probe.
This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Ships within 48 hours · Estimated delivery Jun 21 - Jun 26
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order